Review
Drawings and I/O list are reviewed, or we prepare them ourselves.
WETS AI designs, builds and tests custom PLC control panels in Houston, Texas, with Allen-Bradley, Siemens or Schneider Electric controllers. Each panel is built to UL 508A, wired to your drawings or ours, programmed in-house when you need it, and tested point by point before it ships.
A PLC panel is the brain of a process or machine. It reads every sensor, decides what should happen next and drives the motors, valves and alarms that make it happen.
Every panel is laid out so that power, control and signal wiring are kept apart, every wire is marked, and there is room to work on it later.

We build PLC panels on the three platforms used most in Texas plants.
If your site already has a standard, we follow it.
| Brand | Controllers | Common networks |
|---|---|---|
| Allen-Bradley | Micro800, CompactLogix, ControlLogix | EtherNet/IP |
| Siemens | SIMATIC S7-1200, S7-1500 | PROFINET |
| Schneider Electric | Modicon M340, M580 | Modbus TCP, EtherNet/IP |
We match the platform your plant already runs, so your team can support the panel with the tools and spares they already have.
Spare I/O is agreed up front, so a new instrument does not mean a new panel. The 24 VDC supply is sized with margin and split into protected circuits, so one shorted field device does not take the whole system down.
Heat is checked against the enclosure and its location, especially for outdoor panels in the Texas sun. And the drawings, wire numbers and program tags all use the same names, which saves hours when someone has to troubleshoot at night.
You do not need a complete design to get a quote. These details let us price the panel accurately; anything you do not have yet, we can help define.

Drawings and I/O list are reviewed, or we prepare them ourselves.
The panel is assembled, wired and marked against the drawings.
Point-to-point, ground, insulation and power-up checks are completed.
With the final program loaded, every I/O point is simulated at FAT.
Typical processes our PLC panels control.
Yes. With the final program loaded, every I/O point is simulated and verified, and alarms, interlocks, sequences and communications are tested.
Either. We can engineer the panel from your process description or build it to your drawings.
Yes. Our team writes PLC and HMI programs in-house for Allen-Bradley, Siemens and Schneider Electric.
Mostly NEMA 1 for clean indoor rooms, NEMA 3R for outdoor sites, NEMA 4 for hose-down areas and NEMA 4X where corrosion is a concern. Tell us where the panel will be installed and we will recommend a rating.
About 16 weeks on average from order to shipment. The real figure depends on panel size and on component lead times, so we confirm a schedule with every quotation.
Programs written in-house for Allen-Bradley, Siemens and Schneider Electric, tested at FAT.
Door layouts, touchscreens, pushbuttons, pilot lights and emergency stops.
Drives, bypass, reactors and cooling for pumps, blowers and fans.
Send your drawings or I/O list, or tell us about the process. We will reply with a quotation and a realistic schedule.