PLC & HMI Programming

WETS AI writes PLC and HMI programs in-house for Allen-Bradley, Siemens and Schneider Electric control systems. Each program is written from the agreed control narrative, loaded into your panel in our Houston shop, tested at the factory acceptance test before anything ships, and checked again on site at SAT.

Control Platforms We Program

We program the three platforms most used in Texas plants. We confirm the exact controller and software version with you before programming starts.

BrandTypical controllersProgramming software
Allen-Bradley (Rockwell Automation)Micro800, CompactLogix, ControlLogixConnected Components Workbench (CCW), Studio 5000 Logix Designer
SiemensSIMATIC S7-1200, S7-1500TIA Portal
Schneider ElectricModicon M340, M580EcoStruxure Control Expert

Allen-Bradley, Siemens and Schneider Electric are trademarks of their respective owners. WETS AI is not affiliated with these companies.

How the Program Connects the System

The PLC sits at the centre. The HMI, remote I/O and drives all talk to it over one industrial Ethernet network.

  • One program runs the sequence, interlocks and alarms
  • The HMI shows live values and lets operators run the process
  • Remote I/O shortens field wiring on larger sites
  • Drives report speed, current and faults back to the PLC
Illustration of a control network: an engineering laptop programs the PLC, and the PLC connects through an industrial Ethernet switch to an operator HMI, remote I/O modules and variable frequency drives.
Swipe sideways to see the whole diagram
Siemens SIMATIC HMI on a finished WETS AI control panel
Siemens HMI on a finished WETS AI panel

What We Program

The PLC program carries out the control narrative. The HMI gives operators a clear view of the process and the right controls for their role.

  • Sequences and operating modes
  • Interlocks and permissives
  • Alarms and events
  • PID control loops
  • Network communications
  • HMI screens and navigation
  • Trends
  • User access levels

From Narrative to Running Program

01

Agree the basis

Control narrative, I/O list and HMI requirements are agreed before coding starts.

02

Write and review

The program is written and checked internally against the narrative.

03

Test at FAT

Every I/O point is simulated and the sequences, alarms and interlocks are tested with the panel.

04

Prove at SAT

On site, the program is checked again with the real instruments and equipment.

Programs Your Team Can Work With

A program is only useful if the people who own it can understand it years later. We use consistent tag names, comments on every routine, and a clear structure that follows the sections of the control narrative.

If your company has a programming standard, we follow it. At handover you receive the final program files and backups along with the rest of the panel documentation.

Finished operator panel with Siemens HMI and status pushbuttons
Operator panel with Siemens HMI and status pushbuttons

What You Receive at Handover

When the system is accepted, you get everything your team needs to run and support it without calling us for every change.

We also update existing programs when a plant moves to a newer controller, for example from an older Allen-Bradley or Siemens platform, keeping the sequences your operators already know.

  • Final PLC program files
  • HMI project files
  • Program backups
  • I/O list
  • Recorded drive and overload settings
  • FAT test record

Programming Questions

Do you write the PLC program, or can you load ours?

Both. We can write the program from your control narrative, or load and test a program your team has written.

Is the program tested before the panel ships?

Yes. At the factory acceptance test the PLC and HMI are loaded with the final program, every I/O point is simulated, and alarms, interlocks and sequences are tested.

Can you follow our company programming standard?

Yes. Send us your standard and we will follow its structure, naming and screen conventions.

Can you change or extend an existing program?

Yes. We can modify existing Allen-Bradley, Siemens and Schneider Electric programs, including when a system moves to a newer controller.

Which communication networks do you set up?

Common industrial networks such as EtherNet/IP, PROFINET and Modbus TCP, depending on the platform and the devices in your system.

Related Panels & Services

Design & Engineering

Control narratives, HAZOP and SIL identification, process flow diagrams and panel drawings.

PLC Control Panels

Controllers, I/O, networks and power, built to UL 508A and tested point by point.

Need a Panel Programmed?

Share your control narrative or describe the process. We will quote the programming together with the panel, or on its own.

Call Request a Quote