Check the build
Wiring, ratings and torque are checked against the drawings.
WETS AI builds custom VFD control panels in Houston for pumps, blowers, fans and process motors. We size the drive, its protection and its cooling, build the panel to UL 508A, and record every drive setting during testing so your team knows exactly how the panel left our shop.
A variable frequency drive controls motor speed by changing the frequency and voltage it supplies. The panel around it protects the drive, keeps it cool, and connects it safely to the rest of your control system.

Drives turn a few percent of the power they handle into heat, and that heat has to leave the enclosure. A drive that runs hot trips, derates, or fails early.
Indoor NEMA 1 panels can often use filtered fans. Sealed NEMA 3R, 4 and 4X panels outdoors in Texas also pick up heat from the sun, so they usually need closed-loop air conditioning or a heat exchanger. We work out the heat load for each panel and choose the cooling to match, instead of guessing.
A bypass lets the motor run directly on line power if the drive fails. It is useful for pumps that must keep running, but only where the process can tolerate full speed.
Line reactors and harmonic filters reduce the distortion a drive sends back onto your supply, which some utilities and plants require. Where the motor is far from the panel, a load reactor or output filter protects the motor insulation from voltage spikes.
Power passes through protection and conditioning before it reaches the drive, then on to the motor.
Drives give off heat, and heat shortens drive life.
How we remove it depends on where the panel will live: indoors or out, clean air or dusty, shade or full Texas sun.
| Option | Suits | Keep in mind |
|---|---|---|
| Filtered fans | Indoor NEMA 1 panels in clean, cool rooms | Simplest option, but it brings room air and dust into the panel |
| Air-to-air heat exchanger | Sealed panels with moderate heat loads | Keeps outside air out, but cannot cool below the outside temperature |
| Closed-loop air conditioner | Sealed outdoor panels in hot climates | Cools below ambient; needs a condensate drain and routine maintenance |
We size the option from the calculated heat load and the site conditions, including direct sun on outdoor panels.
Wiring, ratings and torque are checked against the drawings.
Incoming voltage, phase rotation and control power are verified.
Drive parameters are entered and recorded for your files.
Start, stop, speed reference, faults and bypass transfer are tested.
Typical loads our VFD panels drive.
Yes. We build bypass panels with interlocked contactors, so the motor can run on line power if the drive is out of service.
Yes. We enter and record the drive settings during testing. Final tuning against the real load is done on site at SAT.
Allen-Bradley, Siemens and Schneider Electric drives, normally matching the PLC platform and the spares your plant already keeps.
Yes, in a NEMA 3R, 4 or 4X enclosure with cooling sized for the heat load and the sun. We size it for your site.
Long motor leads can cause voltage spikes at the motor. We add a load reactor or output filter when the cable length calls for it.
Full-voltage and soft starters, overloads and SCCR for every motor branch.
Controllers, I/O, networks and power, built to UL 508A and tested point by point.
The 13 checks every panel passes, plus witnessed FAT and SAT on site.
Send the motor list and site conditions, or your drawings. We will size the drive, protection and cooling, and quote the complete panel.